Specification | GRV-OACI-12 | GRV-OACIS-12 | GRV-OAC-12 | GRV-OACS-12 |
Line Voltage | 12–250 VAC | 12–250 VAC | 12–250 VAC | 12–250 VAC |
Current Rating | 0.5 A | 0.5 A | 0.5 A | 0.5 AC |
Recommended Max. Fuse (fast) or Circuit Breaker | 2 A 250 VAC / channel, 6 A 250 VAC common | 2 A 250 VAC / channel, 6 A 250 VAC common | 2 A 250 VAC / channel, 6 A 250 VAC common | 2 A 250 VAC / channel, 6 A 250 VAC common |
Minimum Load Current | 20 mA | 20 mA | 20 mA | 20 mA |
Output Voltage Drop | 1 V | 1 V | 1 V | 1 V |
Off-state Leakage at Nominal Voltage - 60 Hz | 1.25 mA @240 VAC 0.7 mA @ 120 VAC | 1.25 mA @240 VAC 0.7 mA @ 120 VAC | 1.25 mA @240 VAC 0.7 mA @ 120 VAC | 1.25 mA @240 VAC 0.7 mA @ 120 VAC |
Peak Blocking Voltage | 500 V | 500 V | 500 V | 500 V |
Leakage (mA @ 240 V, 60 Hz) | 1.0 | 1.0 | 1.0 | 1.0 |
Operating Frequency | 40 to 60 Hz, 400 Hz | 40 to 60 Hz, 400 Hz | 40 to 60 Hz, 400 Hz | 40 to 60 Hz, 400 Hz |
Turn-on Time | ≤ 1/2 cycle (zero crossing) | ≤ 1/2 cycle (zero crossing) | ≤ 1/2 cycle (zero crossing) | ≤ 1/2 cycle (zero crossing) |
Turn-off Time | ≤ 1/2 cycle (zero crossing) | ≤ 1/2 cycle (zero crossing) | ≤ 1/2 cycle (zero crossing) | ≤ 1/2 cycle (zero crossing) |
Problem Indication | open circuit | none | open circuit | none |
Isolation (field-to-logic) | 300 V working, 1500 V transient (1 minute) | 300 V working, 1500 V transient (1 minute) | 300 V working, 1500 V transient (1 minute) | 300 V working, 1500 V transient (1 minute) |
Isolation (channel-to-channel) | 300 V working | 300 V working | NONE | NONE |
Number of Channels | 12 | 12 | 12 | 12 |
Chassis Power Consumption | 1.3 W | 1.3 W | 1.3 W | 1.3 W |
Wire Size | 28–14 AWG | 28–14 AWG | 28–14 AWG | 28–14 AWG |
Torque, connector screw | 2.5 in-lb (0.28 N-m) | 2.5 in-lb (0.28 N-m) | 2.5 in-lb (0.28 N-m) | 2.5 in-lb (0.28 N-m) |
Torque, hold-down screw | 3.5 in-lb (0.4 N-m) | 3.5 in-lb (0.4 N-m) | 3.5 in-lb (0.4 N-m) | 3.5 in-lb (0.4 N-m) |
Temperature (operating) | -20 °C to +70 °C | -20 °C to +70 °C | -20 °C to +70 °C | -20 °C to +70 °C |
Temperature (storage) | -40 °C to +85 °C | -40 °C to +85 °C | -40 °C to +85 °C | -40 °C to +85 °C |
Relative Humidity (non-condensing) | 5–95% | 5–95% | 5–95% | 5–95% |
Agency Approvals | UL/cUL(Class 1 Div. 2); CE, ATEX(Category 3, Zone 2), RoHS; DFARS; CB Scheme | UL/cUL(Class 1 Div. 2); CE, ATEX(Category 3, Zone 2), RoHS; DFARS; CB Scheme | UL/cUL(Class 1 Div. 2); CE, ATEX(Category 3, Zone 2), RoHS; DFARS; CB Scheme | UL/cUL(Class 1 Div. 2); CE, ATEX(Category 3, Zone 2), RoHS; DFARS; CB Scheme |
Warranty | Lifetime | Lifetime | Lifetime | Lifetime |