A rack-mountable 15A, 120V AC power controller, conditioner, and surge protector for professionally installed AV and IT systems. Provides switching of three separate outlet banks, plus energy monitoring of all connected devices. Features network connectivity, web browser setup, event logging, ping monitoring, temperature sensing, and UL 1449 compliance.

Get Custom Programming from 4TEC

Price: $1,150.00
    Quantity:
    Availability: In Stock
    Usually ships In 24 - 48 hours

    Item #: PC-200

    Description

    The PC-200 is a professional grade, rack-mountable power conditioner and controller designed to provide 120 Volt AC power distribution, switching, surge protection, noise filtering, and energy monitoring for Crestron® control systems, AV systems, computers, and other equipment. Eight switched outlets are provided on the rear panel, plus a single unswitched convenience outlet is provided on the front. All nine outlets are protected, filtered, and monitored. The switched outlets are arranged in four banks of two, three of which are turn-on delay-adjustable when controlled from the front panel power switch. The same three outlet banks are also individually controllable via a control system to enable selective switching of devices, on/off power sequencing, load-shedding, and other custom power control functionality.[1]

    Built-in RMS voltage and current monitoring enables logging and reporting of the line voltage, current, power, and energy usage at the input. An external temperature sensor is included to keep tabs on heat conditions within the equipment rack or room. Network connectivity allows for setup and operation using a web browser, with extensive custom control and monitoring capabilities enabled through integration with a Crestron control system, the MyCrestron.com residential monitoring service, the Crestron Fusion® Cloud enterprise management service, or an SNMP client.[1,2]

    Power Conditioning
    A quality power conditioner is an essential component of any professional system to prevent sudden equipment failure due to lightning and electrical disturbances, to prolong the lifespan of that equipment, and to maximize overall system performance during everyday operation. The PC-200 includes the following power conditioning features:

    • Surge Protection — Provides protection against surges and spikes in the AC power line caused by lightning and other electrical disturbances
    • Under/Over Voltage Cutoff — Shuts off power to the rear panel outlets if the line voltage strays beyond the normal operating range, which is adjustable on the PC-200
    • Thermal Breaker — Disrupts power to all outlets in case of an overload condition
    • EMI/RFI Noise Filtering — Prevents electromagnetic and radio frequency interference that can negatively impact sound and video quality
    • Wiring Fault Detection — Detects faulty wiring of the incoming AC power line and shuts off power to the rear panel outlets until the fault is corrected [3]

    Four-Stage Adjustable Turn-On Delay
    The switched outlets on the PC-200’s rear panel are arranged in four banks, with two outlets per bank. When operated by its front panel power switch, the first bank turns on immediately while the other three banks can be configured to turn on in any order according to the delay time set for each bank. Each bank is independently adjustable to provide up to 10 seconds of delay before turning on, ensuring that the connected equipment gets powered up in proper order with sufficient time for each piece to stabilize. This helps to prevent dangerous transients that can damage delicate components and potentially trip the main circuit breaker. It can also help to prevent audible pops and thumps through connected audio equipment at power-up. Delayed turn-on is initiated by turning on the front panel power switch, or by applying power to the main line input following a power outage or through an externally switched circuit.

    Three Remote-Controllable Switched Outlet Banks
    When connected to a local area network, three of the four outlet banks on the PC-200’s rear panel can be turned on or off independently using a web browser or control system. The other bank is always on as long as the front panel switch is turned on. This energy-saving feature allows select components to be powered down when not needed. Through integration with a control system, custom functionality can be programmed to enable control from a touch screen, keypad, remote, or mobile device. Sequential power-up and power-down functionality can be enabled through programming of the control system. For systems employing a backup generator or UPS, load-shedding can be performed to shut down unnecessary components during a power outage.[1]

    Energy Monitoring
    By sensing the incoming line voltage and the total device load, the PC-200 facilitates a host of solutions for monitoring, automating, and troubleshooting a system.

    • Voltage monitoring allows fluctuations in the power line to be tracked and logged, helping to identify and document problems with the power utility or building wiring.
    • Energy monitoring provides the real power consumption (watts), current draw (amps), and energy usage (watt-hours) for all of the connected devices combined.
    • By connecting and testing one component at a time, the PC-200 allows power-hungry equipment to be identified and replaced with more efficient equipment.
    • High inrush current devices can be identified to assist in optimizing the configuration of power sequencing schemes.
    • Overall energy usage can be tracked and logged to identify trends and reform energy-wasting behaviors.
    • System usage can be tracked to inform the scheduling of maintenance and future purchasing decisions.
    • An alert notification can be sent if there’s a sudden or abnormal drop in current draw, potentially indicating a device has been shut off improperly or disconnected due to theft (effective only when outlets are switched on).

    Ambient Temperature Sensing
    The PC-200 offers a complete equipment protection solution by monitoring the ambient temperature within the equipment cabinet or room to prevent overheating. The included temperature sensor connects to the rear of the PC-200 and features a choice of magnetic or adhesive mounting for easy placement within a typical equipment rack enclosure. The over-temperature cutoff threshold can be set to shut down power to the system if conditions exceed a safe operating temperature. Through a control system, the temperature measurement can be utilized to regulate the operation of cooling fans or air-conditioning equipment to keep equipment running cool.

    Ping Monitoring
    No matter how well a system is designed and programmed, even the finest control system or computer has the potential to lock up and stop responding once in a while. The PC-200 can be configured to detect an unresponsive device by sending it a ping command at regular intervals. If the ping request is not returned after four tries, the outlet bank feeding the monitored device cycles off and on to reboot the device, quickly restoring normal operation without any human intervention.

    Built-In Logging
    Events such as power surges, over/under voltage conditions, over-temperature conditions, ping failures, outlet switching activity, and sudden changes in current draw (indicative of a device being improperly shut off or disconnected) can all be logged as they occur to document the time and cause of problems and to track system usage. All sensor readings are logged at a configurable interval as short as five seconds providing a minimum of one week’s worth of data. Logs can be retrieved periodically to record a detailed history of events and energy usage over time.

    Remote Management & Control
    The PC-200 integrates neatly into any system or facility. Used alone, it can be set up and managed through a web browser. It can also be configured to send email notifications in case of certain specified events. Integration with the MyCrestron.com residential monitoring service provides a cloud based solution for homeowners to monitor and manage the PC-200 as part of a complete Crestron home automation system. Or, Crestron Fusion Cloud provides an enterprise solution for corporations and universities to manage rooms using the PC-200 throughout a building or campus. Built-in SNMP support enables integration with third-party IT management software, allowing network administrators to manage one or many networked PC-200s in an IT-friendly format. And of course, the PC-200 can be integrated with a Crestron control system via Ethernet or Cresnet® to enable control and monitoring through a touch screen, handheld remote, or mobile device.[1,2]

    UL® 1449 Certified
    The PC-200 has been tested and certified by UL as compliant with the UL 1449 safety and performance standard for surge protective devices (SPD).

    Key Features
    • Rack-mountable power conditioner and controller
    • Eight switched rear panel outlets, arranged in banks of two
    • Adjustable turn-on delay and remote switching per each of three banks
    • One unswitched front panel outlet
    • Built-in current sensing and energy monitoring
    • Line voltage monitoring
    • Professional grade surge protection
    • UL® 1449 Type 3 Listed
    • Thermal breaker overload protection
    • Adjustable over-voltage and under-voltage cutoff
    • EMI and RFI noise filtering
    • Wiring fault detection [3]
    • Ambient temperature sensing and over-temperature cutoff
    • Ping monitoring (device lockup detection and reboot)
    • Built-in energy usage and event logging
    • Front panel main power switch and status indicators
    • Easy setup and operation via web browser
    • Crestron® control system integration via Ethernet or Cresnet®
    • Remote management via MyCrestron.com, Crestron Fusion® Cloud, or SNMP [2]
    • Single-space 19 inch rack-mountable
    • Rated 15 Amps at 120 Volts AC
    • Limited Lifetime Product Warranty
    • Limited 5 Year Connected Equipment Protection Warranty

    Specifications

    Power Conditioner & Controller
    Maximum Output Current, Total15 Amps @ 120 Volts AC
    Maximum Output Current, Per Outlet/Bank15 Amps @ 120 Volts AC (subject to a maximum total output current of 15 Amps for all outlets combined)
    Filtration40 dB @ 100 kHz, 50 dB @ 300 kHz, with 50 Ohm load
    Surge Protection ModesL-G, L-N, N-G
    Surge Protection ShutoffShuts off rear outlets if surge protection is compromised
    Energy Dissipation2000 Joules per Mode
    Clamping Voltage370 Volts
    Clamping Time1 ns
    Wiring Fault DetectionShuts off rear outlets if a wiring fault is detected at the input [3]
    Voltage Sensing Range90.0 to 160.0 Volts rms ±1%, measured at input
    Current Sensing Range0.4 to 15.0 Amps rms ±1% (resistive), measured at input
    Ambient Temperature Sensing Range-13.0° to 221.0° ±4° F (-25.0° to 105.0° ±2° C)
    Under Voltage CutoffAdjustable 90 to 110 Volts, shuts off rear outlets if input drops below set value
    Over Voltage CutoffAdjustable 130 to 147 Volts, shuts off rear outlets if input exceeds set value
    Over Temperature CutoffAdjustable -13.0° to 221.0° F (-25.0° to 105.0° C), shuts off rear outlets if input exceeds set value
    Turn-On Delay Adjustment0.1 to 10.0 seconds, adjustable per each of rear outlet banks "DELAYED ON 1 – 3"
    Power
    Line Power15 Amps @ 120 Volts AC, 60 Hz
    Cresnet Power Usage0 Watts
    Communications
    Ethernet10/100 Mbps, auto-switching, auto-negotiating, auto-discovery, full/half duplex, TCP/IP, UDP/IP, CIP, DHCP, SSL, TLS, SNMP, Web Server, SMTP e-mail client, web browser setup and control, Crestron control system integration, Crestron Fusion Cloud monitoring, MyCrestron.com monitoring [2]
    CresnetCresnet slave mode
    Connectors
    120V~ 15A 60Hz(1) Attached 9.8 ft (3 m) grounded AC power cord with NEMA 5-15P plug;
    Line power input
    SWITCHED ON 1(2) NEMA 5-15R AC power outlets;
    Locally switched 120 Volt AC power outlet bank
    DELAYED ON 1 – 3(6) NEMA 5-15R AC power outlets;
    Comprises three banks of two switched 120 Volt AC power outlets;
    Locally switched with adjustable turn-on delay per bank;
    Remote switchable per bank
    TEMP(1) 2-pin 3.5 mm detachable terminal block;
    Connection for external temperature sensor (included)
    Y, Z, G(1) 3-pin 3.5 mm detachable terminal block;
    Cresnet slave port
    LAN(1) 8-pin RJ45 jack;
    10Base-T/100Base-TX Ethernet port
    G(1) 6-32 screw;
    Chassis ground lug
    ALWAYS ON (front)(1) NEMA 5-15R AC power outlet;
    Unswitched 120 Volt AC power outlet
    Controls & Indicators
    PWR(1) Bi-color green/amber LED, indicates line power is present, illuminates amber when the power switch is off and while booting, illuminates green when the power switch is on and the unit is operating normally, turns amber if the rear outlets have been shut off due to a fault condition
    FAULT(1) Red LED, indicates any of the following fault conditions: surge protection is compromised, line and neutral are reversed, or no ground is detected [3]
    PROTECT(1) Green LED, indicates surge protection is fully functional
    SHUTDOWN(1) Amber LED, indicates power to the rear outlets is shut off due to an over-voltage, under-voltage, over-temperature, line input miswire, missing ground, or compromised surge protection fault condition
    HW-R(1) Recessed pushbutton, initiates a hardware reset of the internal CPU (does not affect outlets)
    SETUP(1) Recessed pushbutton & red LED, for touch-settable ID (TSID) and Ethernet autodiscovery
    Power Switch(1) Rocker switch, "On" position initiates turn-on delay sequence to the rear panel outlets, "Off" position turns all rear outlets off immediately
    THERMAL BREAKER (rear)Disrupts power to all outlets in case of an overload condition, press to reset after overload condition is resolved
    LAN (rear)(2) LEDs, green LED indicates Ethernet link status, amber LED indicates Ethernet activity
    Environmental
    Temperature32° to 113° F (0° to 45° C)
    Humidity10% to 90% RH (non-condensing)
    Construction
    ChassisSteel, black finish
    Front PanelExtruded aluminum, black finish, polycarbonate label overlay
    Mounting1 RU 19-inch rack-mountable (rack ears included)
    Temperature SensorAdhesive or magnetic mount, 9.8 ft (3.0 m) attached lead
    Dimensions
    Height1.73 in (44 mm)
    Width17.32 in (440 mm);
    19.00 in (483 mm) with rack ears
    Depth10.56 in (269 mm)
    Weight
    8.2 lb (3.8 kg)
    Compliance
    UL 1449 Type 3 Listed